Features


 

  8 Color Modes

●  High Resolution Images

●  Operating Modes: B, B+A, B+B and A

●  8-Image Memory

●  5 Sections Adjustable TGC

●  Cineloop for 5.6 seconds

●  Manual Correction of Axial Measurement under A-mode

●  Multi-groups of Calipers for Distance Measurement

●  Measuring Mode: Contact & Immersion

●  8 Groups of Reading Average with Standard Deviation under A-mode

●  High Definition LCD Monitor

●  B-Probe Protection: Automatic Stop after 10 minutes of Continuous Scanning

●  Trackball for Easy Measurement and Operation

●  Optional Image Output: Video Printer or Workstation

 

 

 

 

 

 

TGC

TGC (Time Gain Control)

enhances segmental imaging gain.

5-segment TGC adjustable within range from -30dB to 0dB.

Applicable default and customized settings. 

B+B

Dual-B mode enables

image/video review and comparison.

Dedicated for omni-dimensional

ocular disease observation.


ZOOM AND DELAY

Enlarge diagnostic images by different zooming levels.

6 zooming rates adjustable.

Diagnostic image shifting

from posterior segment to anterior segment.


POWERFUL POST-PROCESSING

Distance and area measurement.

Simultaneous display of multiple groups of

distance and area reading.

Freezing diagnostic images storage & dynamic cine review.

8 different color codes.

 

FIVE-POINT MEASUREMENT

Innovative AL measurement method under A+B mode.

Combine biometric measurement with ocular image display.

 

AL & IOL

Integration of AL measurement and IOL calculation.

Diagnostic solution for cataract surgery.

Reading averaging and standard deviation

improve reading accuracy and reliability.

Contact & Immersion measuring methods.

4 automatic measuring modes:

Normal, Cataract, Aphakic and Special.

Manual measuring also available.

 

IOL CALCULATION

6 popular IOL formulae:

SRK-T, SRK-II, BINKHOST-II,

HOLLADAY, HOFFER-Q and HAIGIS

Dual-formula display for result comparison.


PC CONNECTION

Patient management system enables

massive patient case study and storage

and assists to generate

customized clinical report and printing.

 

Clinical Gallerww.png

Accessories

22.png

Options

11.png

 

B-Scan

Display Mode:  B, B+B, B+A, A

Probe Frequency:  10MHz

Scanning Method:  Mechanical sector scan

Resolution: Axial≤0.2mm, Lateral≤0.4mm

Gain: 0-98dB adjustable

Zoom: 34mm - 60mm, 6 steps selectable

TGC: -30dB - 0dB dynamic, 6 Points manually adjustable

Variable Delay Depth: 0-15 mm

Post Processing:  4 groups of curves (Linear, Logarithmic, Exponential, S-curve)

Distance & Area Measurement

Dynamic Replay:  for 5.6 seconds

56 images displayed continually or separately

Probe Hibernation: over 10 minutes

Gray Scale: 256 levels




A-Scan

Probe: 10MHz with Fixation Red Light

Resolution: 0.01mm

Biometry Accuracy: ≤±0.06mm

Gain: ≥98dB with an adjustable range of 0-55dB

Measuring Range: 15-39mm

Measuring Parameters: Anterior Chamber Depth, Lens Thickness, Vitreous Length and Axial Length

Measuring Method: Immersion and Contact

5 Different Measuring Modes: Automatic (Normal, Dense Cataract, Aphakic and Special); Manual

Calculation of 8 groups' average with Standard Deviation (S.D)

IOL Formula:  SRK-T, SRK-II. BINKHOST- II. HOLLADAY, HOFFER-Q and HAIGIS




Standard Configuration

ODM-2200 Ultrasonic A/B Scanner

10MHz B Probe

10MHz A Probe

Foot Switch

Test Object




Other

Power Supply: AC 100-240V, 50/60Hz

Weight:  6Kg Without LCD Screen

Dimension:   460 x 420 x 80 mm


10MHz

  • Retina Detachment

  • Vitreous Haematocele

  • Vitreous Organization